tekno-support

GASEOUS FIRE EXTINGUISHING:

 

Dry chemical and wet foam extinguishing systems, protected areas, damage to the devices,the duration of suppression is desired to be kept short in cases where it is preferred. Fm200 andCO2 gas can be used. FM 200, Halon gas began to be used instead. Eco-friendly and life isshort atmospheric gas. Ozana doesn't hurt. The ODP value is 0. Colourless and odourless.

FM 200 gas fire extinguishing systems,FM 200 gas fire and corrosive and electrically conductivein the aftermath of the lack of, due to the fact that, in the protection of the area where sensitive equipment is located is preferred. A low concentration with high extinguishing effect. Fm200 extinguishing concentration is also highest in the presence of living things can be used withconfidence even in. FM 200 systems for Class A surface fires, Class B flammable liquid fires andclass C fires in electrical equipment is active. The compression ratio is high compared to other gases because the low space requirement and hence the number of tubes in the tube that you will need.IT, I nformation Centres, archives, museums, medical devices, rooms, stores, libraries, and fm200 gas fire extinguishing systems are used are places where historical buildings.


CO2 in air 50% more than a dense, colorless, odorless, and electrically non-conductive gas.Is kept as a liquid in high pressure cylinders. Although the use of Halon gas has diminished with the output of a system due to the low filling cost, it is preferable for the preservation of the environmentis still  unmanned.

FM200 gazlı söndürme sistemleri, FM200 gazının elektriksel olarak iletken ve korozif olmaması ve  yangın  sonrasında  artık  bırakmaması  sebebiyle  hassas  cihazların  bulunduğu  alanların korunmasında  tercih  edilir.  Düşük  konsantrasyon  ile  yüksek  söndürme  etkisi  sağlar.  Ayrıca FM200 en yüksek söndürme konsantrasyonunda bile canlıların bulunduğu ortamlarda güvenle kullanılabilir. FM200 sistemleri Class A yüzey yangınlarında, Class B yanıcı sıvı yangınlarında ve Class  C  elektrikli  ekipmanların  yangınlarında  etkindir.  Sıkıştırma  oranının  diğer  gazlara  oranla yüksek  olması  sebebiyle  tüp  sayısı  ve  dolayısıyla  tüplerin  ihtiyaç  duyacağı  alan  gereksinimi düşüktür. IT, bilgi merkezleri, arşivler, müzeler, tıbbi cihaz odaları, depolar, kütüphaneler ve tarihi binalar FM200 gazlı söndürme sistemlerinin kullanıldığı yerlerdir.

CO2 havadan %50 daha yoğun, renksiz, kokusuz ve elektriksel olarak iletken olmayan bir gazdır. Yüksek  basınçlı  tüplerde  sıvı  olarak  tutulur.  Halon  gazlı  sistemlerin  çıkışıyla  kullanımı  azalmış olsa da düşük dolum maliyeti sebebiyle insansız ortamların korunmasında hala tercih edilir.


    • Inert Gaseous Extinguishing Systems 
    • CO2 Gaseous Extinguishing Systems 
    • FM-200 Gaseous Extinguishing Systems 
    • Water Mist System 
     

  • CO2 Söndürme

  • FE-13 Söndürme FM-200 Söndürme 

  • Su Sisi Söndürme


WATER MIST SYSTEMS: 
 

Systems with these properties; water from high pressure nozzles by spraying water droplets on the micron scale is based on the reduction of. Due to the high heat and the latent heat of water, the level of cooling,the best FireExtinguisher. Classic is used and a large amount of water extinguishing systems located in the neighborhood turned off the water, the risk of damage to materials and equipment is high. The system needs a very small amount compared to classical wet sprinkler systems to water. A (wood, paper), B (liquid fuel) and C (Electrical) fire fighting and effective on Class A fires, as did the fast re-formation, combustion suppressing prevents.

3 water spray feature, are effective against fires.
1 . Choke: Es volume with water evaporating oxygen detract from the environment.

2.Sorption: Micrometric size of the water droplets creates a large surface heat collector.The temperature 500c from 40C falls to within a few seconds.

3.Water Fog: Absorb the radiated heat and prevents the damage of the fire. Due to the sudden evaporationof small water droplets absorbs heat from the environment.


Water mist systems, gas extinguishing systems, which is a suitable alternative to be used in conjunctionwith other modern fighting systems. I n addition to applications in industrial facilities, turbine rooms,machine rooms,generator rooms, data processing centers, archives, and warehouses the use of tunnels isincreasing.

1. Boğma: Buharlaşan su, kendisiyle eş hacimde oksijeni ortamdan uzaklaştırır.

2. Soğurma: Mikrometrik boyuttaki su damlacıkları büyük bir ısı toplayıcı yüzey oluşturur. Oluşan sıcaklık birkaç saniye içerisinde 500C’den 40C’ye düşer.

3.  Su  Sisi: Yayılan  ısıyı  absorbe  ederek  yangının  vereceği  zararı  engeller.  Küçük  su  zerreciklerinin  ani buharlaşması nedeni ile ortamdan ısıyı emer.

Gazlı söndürme sistemlere uygun bir alternatif olan su sisi sistemleri diğer modern söndürme sistemleriyle birlikte  kullanılabilir.  Endüstriyel  tesislerdeki  uygulamalarının  yanısıra  türbin  odaları,  makine  daireleri, jeneratör odaları, bilgi işlem merkezleri, arşivler, tüneller ve depolarda kullanımı artmaktadır.



ADVANTAGES



The environment and does not damage the ozone layer

The equipment is suitable for the protection of

Can be used with confidence in areas with human

The lowest level of water damage

Can be applied in local open spaces

Demineralized water does conduct electricity

because it is used Provides fast temperature drop

independent pump system and kit include Economic. Extinguishant is the cheapest

Provides effective suppression of flammable liquids




USAGE AREAS



Labour Offices Hotel Rooms

Restaurants, kitchens, ovens

and cooking systems Subways,

Tunnels, Archives, Libraries, Museums

Cable Ducts

Stores Material

Data processing centres Hospitals

The production of food and energy

Hospitals

Energy Plants

Chemical Storages